View and Download Trane VAV-IN-24 instruction manual online. Trane VAV-IN-24, Unit Control Module (UCM) 4.2 Retrofit Model VAV User Manual. View and Download Trane XR 90 SERIES feature overview manual online. Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace with Single-Stage Fan Assisted Combustion System. XR 90 SERIES furnace pdf manual download. Also for: Xr 90, Tux040c924d. UCP, Reliatel, and IntelliPak control units. It has the following features: † A liquid crystal display. And Maintenance Manual Trane X Installation, Operation And Maintenance Manual (32 pages) Programmable Zone Sensor. INSTALLATION MANUAL Pdf. Zone Sensor Module. The unitary economizer module (UEM), must be connected in-line between the defrost module (DFM) and the unitary control processor (UCP). This is accomplished by locating the polarized plug (PPF8) from the UCP and the polarized plug (PPM8) from the DFM in the control box. They are connected to each other,and located between the UCP and the DFM.

Loading...

Installation

Unit Control Module (UCM) 4.2 Retrofit

Model VAV

Models

Ucp

“A” and later Design Sequence

VAV

NOTICE:

Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully.

Trane ucp module manual pdf

WARNING – Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Trane Ucp Module Manual User

CAUTION – Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.

CAUTION – Indicates a situation that may result in equipment or property-damage-only accidents.

General

The purpose of this installation manual is to provide application, functional and calibration information for the Trane Retrofit package. Examples and charts are provided to enhance the understanding of this information.

Introduction

The DDC/VAV retrofit kit consists of the UCM control assembly, a Honeywell™ or Belimo™ actuator (both optional), and various accessories such as zone sensors, transformers, flow sensors, etc. This manual is intended to show how to apply, install and configure the DDC/VAV Retrofit kit. It is intended to provide information specific to the VAV retrofit. Refer to VAV-SVX01C-EN for complete DDC/VAV system wiring, installation and programming instructions.

Applications

Trane Ucp Module Manual Pdf

The retrofit kit may be applied to pneumatic terminals by replacing the pneumatic actuator with an electric actuator or electrically controlled terminals by either using the existing electric actuator or by replacing it with one provided by Trane.

The kit may be used on existing shutoff, shutoff hot water reheat, shutoff with up to three stages of electric heat, and fan powered (both parallel and series) cooling only, hot water, and electric reheat units.

Note: Fan powered units have only two stages of reheat available.

Diagram

Dual duct units may also be retrofitted using two sets of controllers. The kit has also been applied to constant volume reheat systems where the retrofit kit is used to control duct coils.

The kit has been tested on VAV terminals of several major manufacturers. It is mandatory for unit to have an external shaft to function properly with the direct coupled actuators offered.

© 2005 American Standard All rights reserved

VAV-IN-24

Trane Ucp Module Manual Transmission

Contents

Trane Ucp Manual

Trane Ucp Module Manual

Trane Ucp Module Manual User

Installation/Startup/Commissioning

2

Notice/Introduction

2

Application

2

Hardware

4

Installation

5

Commissioning

6